STEP 1: Measure 100Hz/120Hz Peak-to-Peak AC Ripple on the +5V / +12V Bulk Filter Cap
[node-1]
Set your oscilloscope to AC Coupling, 200 mV/div, and 2.5 ms/div (20 MHz bandwidth limit ON). Probe directly across the main bulk filter capacitor (e.g. C19 2200µF / C88 1000µF on C64, or C303/C304 on Amiga) under full system load. Measure the peak-to-peak sawtooth ripple amplitude (mVpp).
Expected Reading: < 50 mVpp clean regulated rail (post-regulator) or < 350 mVpp on raw unregulated bulk DC before the 7805/7812.
STEP 2: Check Linear Regulator (7805 / 7812) Input-to-Output Dropout Margin
[node-2]
Switch oscilloscope or multimeter to DC Volts and measure Pin 1 (Input) of the 7805 (+5V) or 7812 (+12V) regulator at the bottom of the ripple trough. Verify that Input Voltage remains at least 2.0V above the regulated output (e.g. ≥7.2V into a 7805, ≥14.2V into a 7812).
Expected Reading: 7805 Input ≥ 7.2V DC; 7812 Input ≥ 14.2V DC. Below this dropout threshold, ripple punches straight through to the logic rail.
STEP 3: Check Local IC Decoupling & Audio/Video AC Coupling Capacitors
[node-3]
Probe audio output coupling caps (e.g. C91 100µF on C64 SID Pin 27, or C324/C334 22µF SMD on Amiga Paula) — compare upstream vs. downstream signal amplitude. Inspect SMD electrolytic pads (Amiga 600/1200, Game Gear, DMG-01) under magnification for fishy odor, dull grey solder corrosion, or lifted copper traces.
Expected Reading: Full audio/video swing across the coupling capacitor with zero DC leakage on the output side and clean, shiny solder pads.
[ISOLATED FAULT: RES-BULK-CAP] Fault Isolated: High-ESR Bulk Filter Capacitor (>100 mVpp Rail Ripple)
VERDICT
Excessive 100/120Hz sawtooth ripple on the DC rail confirms that the primary reservoir/filter electrolytics have dried out and lost effective capacitance.
[ISOLATED FAULT: RES-REG-DROPOUT] Fault Isolated: Linear Regulator Dropout / Bridge Rectifier Diode Open
VERDICT
The pre-regulator DC rail is sagging below the minimum 2V dropout headroom required by the 7805/7812 regulator.
[ISOLATED FAULT: RES-COUPLING-CAP] Fault Isolated: Open/Leaky Audio or Video Coupling Capacitor & Trace Corrosion
VERDICT
Signal attenuation, muffled audio, or DC offset hum across the coupling stage indicates dried-out or leaking coupling capacitors.
[ISOLATED FAULT: RES-RAILS-HEALTHY] Verification Passed: Power Rails, Ripple & Coupling Capacitors Within Spec
VERDICT
All measured DC supply rails, AC ripple levels (<50 mVpp), and coupling stages pass bench specification. If performing a preventive recap, use the verified board BOM below.